Support for yourCooktop

Fault FE49

Fault FE49 appears on the display of an induction cooktop cooking zone.

The fan is being blocked by objects in a drawer below the cooktop, or by dust or similar substances.

Check whether the fan is being blocked by objects in a drawer below the cooktop, or by dust or similar substances, and remove the blockage accordingly.

There is insufficient ventilation for the appliance cooling system.

Check that the minimum clearances for installing the cooktop, as specified in the operating and installation instructions, have been adhered to.
There must be a clearance of at least 1/2" (15 mm) between the bottom edge of the cooktop and the interim shelf or oven.

Once this clearance has been established, you must disconnect the cooktop from the power supply in order to clear the fault message.

If the fault persists, please contact us or book a repair appointment online.

Operating Instructions finder

Operating Instructions finder

Here you will find the operating instructions for your Miele appliances
Find your manual
Book a technician

Book a technician

We are happy to take your repair booking online or by telephone
Plan a visit
Contact us

Contact us

Visit our Contact us page to see the different ways you can speak to us.