Compare
PG 8593 [WW AD]
Laboratory glassware washer with liquid dispensing & hot air drying DryPlus.
- Performance/cycle, e.g., 128 laboratory bottlesFurther stacking options
Alternatively, 98 pipettes can be reprocessed per cycle with further laboratory glassware. - Safety through monitoring - wash pressure and spray arm monitoringFor a reliable result
Outstanding reprocessing results are achieved because the jet pressure and spray arms are monitored continuously and a decline in jet pressure or load blockage is detected immediately - 72% less water consumption compared to predecessor model*Save water with flawless resultscompared to standard program for G 7893
The variable-speed heating pump adjusts its speeds and thus the wash pressure in line with the relevant requirements in the program blocks – high pressure facilitates the removal of stubborn soiling, while low pressure guarantees the complete soaking of all the load items. As a result, the consumption of water and energy remains particularly low with optimum wash pressure at all times. Outstanding results while ensuring sustainable use of resources. - Efficient hot air drying - DryPlusEfficient drying
The hot air drying feature DryPlus is the perfect solution for hollow instruments. The upstream H13 HEPA filter ensures optimum particle separation from the drying air. The filter can be easily accessed via a cover in the front of the toe-kick area. - Total security - link to process documentation possibleEnd-to-end documentation
The optional addition of a module for process documentation is provided via a communication slot. The Ethernet module is used for documentation via software. The RS 232 module must be used for documentation within a USB solution or via a printer.
Product benefits
Subject to technical changes; no liability accepted for the accuracy of the information given! Figures as examples for showing the product benefit.
Subject to technical changes; no liability accepted for the accuracy of the information given! Figures as examples for showing the product benefit.
Subject to technical changes; no liability accepted for the accuracy of the information given! Figures as examples for showing the product benefit.
Subject to technical changes; no liability accepted for the accuracy of the information given! Figures as examples for showing the product benefit.
Subject to technical changes; no liability accepted for the accuracy of the information given! Figures as examples for showing the product benefit.

Clear text display
Text display
Everything at a glance: The display shows everything as clear text in the country-specific language.

AutoClose*European patent EP 1 733 675 B1
Automatically closing door
A light touch is all it takes: With AutoClose, the door closes by itself.

Large selection of components
Reprocess flexibly
Flexible and comprehensive components for optimum cleaning performance and a variety of reprocessing options.
Subject to technical changes; no liability accepted for the accuracy of the information given! Figures as examples for showing the product benefit.
Product details
PG 8593 [WW AD]
EAN 4002515645055 / Article number 62859301CDN / Material number 10254340
EAN 4002515645055 / Article number 62859301CDN / Material number 10254340
AutoClose – automatic door lock | |
---|---|
Buzzer, acoustic signal at end of program | |
Easy-to-service construction |
Suitable for laboratories |
---|
Laboratory flasks per cycle [number] | 128 |
---|---|
Pipettes per cycle [number] | 98 |
Circulation pump, Qmax in gal/min (l/min.) | 132.1 (500) |
---|---|
Maximum final rinse temperature in °F (°C) | 199 (93) |
Usable wash cabinet volume in ft³ (l) | 5.12 (145) ft³ (l) |
Tested operating hours | 15000 |
Control type | TouchControl |
---|---|
Program selection | Touch on metal |
Max. delay start in h | 24 |
Programmability | programmable |
Programs [number] | 15 |
Free program slots [number] | 2 |
A0 value controls | |
Time left display | |
Program sequence indicator | |
Choice of display language |
Electrical connection | 3 AC 208V 60HZ |
---|---|
Electric heater rating in kW | 5.4 |
Total rated load in kW | 6.2 |
Fuse rating in A | 20 |
Length of power cord in ft (m) | 5 (1.8) |
Electrical connection | 2 AC 208V 60HZ |
---|---|
Electric heater rating in kW | 5.4 |
Total rated load in kW | 6.2 |
Fuse rating in A | 30 |
Cold water [number] | 1 |
---|---|
Cold water for steam condenser [number] | 1 |
Hot water [number] | 1 |
Fully demineralized water [number] | 1 |
Required flow pressure in kPa | 200-1000 |
Maximum drain pump height (delivery head) in in (cm) | 39 3/8 (100) |
Maximum water hardness (cold water / hot water) in (mmol/l) | 62.595 (10.7) |
Drain pump [DN] | 0.866 (22) |
Water protection system | Waterproof system |
Integrated drying unit | |
---|---|
Fan in kW | 0.3 |
Heater element in kW | 2.2 |
Air throughput in m³/h | 60 |
Time settings in 1-minute steps | 0-120 |
HEPA filter class | H13 |
HEPA filter filtration efficiency (in accordance with DIN EN 1822) in % | 99.95 |
HEPA filter service life in h | 200 |
External dimensions, net height in in. (mm) | 32 7/8 (835) |
---|---|
External dimensions, net width in in. (mm) | 23 5/8 (600) |
External dimensions, net depth in in. (mm) | 23 5/8 (600) |
Packaging dimensions, gross height in in. (mm) | 37 1/16 (940) |
Packaging dimensions, gross width in in. (mm) | 26 5/8 (675) |
Packaging dimensions, gross depth in in. (mm) | 29 3/8 (745) |
Wash cabinet, usable height in in. (mm) | 20 1/2 (520) |
Wash cabinet, usable width in in. (mm) | 20 7/8 (530) |
Wash cabinet, depth of upper basket in in. (mm) | 18 11/16 (474) |
Wash cabinet, depth of lower basket in in. (mm) | 20 1/2 (520) |
Net weight in lb (kg) | 171.961 (78) |
Gross weight in lb (kg) | 187.393 (85) |
Emission sound pressure level in the workplace | <lt/>70 dB(A) re 20 µPa |
---|---|
Heat dissipation into the room in MJ/h | 1.4 |
Special 93°C–10' | |
---|---|
Standard | |
Universal | |
Intensive | |
Inorganic materials | |
Organic materials | |
Injector Plus | |
Pipettes | |
Plastics | |
Mini | |
Oil |
1 dispenser pump for liquid cleaning agent | |
---|---|
Spray pressure monitoring | |
Spray arm monitoring | |
Interface for process documentation (optional) | |
Multi-component filter system | |
Variable-speed heating pump | |
Load carrier - direct coupling | |
DryPlus | |
In-door salt container | |
Miele Service optical interface | |
Wash cabinet seamlessly welded using laser technology | |
Extensive components (option) |
RS 232 serial interface (optional) | |
---|---|
Ethernet interface (optional) | |
External dispenser modules |
IP safety class according to EN 60529: IP 21 | |
---|---|
EN 61010-1 | |
EN 61010-2-040 | |
c CSA us |
Additional accessories and consumables
Find additional accessories and consumables to go with this product

Additional accessories for laboratory technology
Find here the accessories that can be bought additionally for this product.

Additional consumables for laboratory technology
Find here the consumables that can be bought additionally for this product.